PRODUCT

ENTERPRISE BRIEF INTRODUCTION

COMMODITY:Three Phase Anti-backcurrent Smart Power Meter

Model NO:DTSD9866-CD4-NL

Application Scenarios:Used in photovoltaic power generation system to actively prevent or control the situation of reverse current when the power generation power is greater than the actual load.

PRODUCT OVERVIEW

Using Din rail installation,especially suitable for applications with small Installation space,industry standard wide temperature

LCD  screen,with Good high and low temperature display characteristics,to achieve full power measurement and display,including

dynamic alarm,switching Input and output status,SOE event recording,complex rate,harmonics,etc,support RS485 communication,

can be configured to  Modbus -RTU Protocol.

Working Principle:

The Meter to be used with the inverter and the inverter adjusts the output power in real time through the power size and direction

of the network access port collected by the RS485 communication reading meter to achieve the anti-backflow function.

KEY FEATURE:   

  • Full power measurement & metering
  • DIN35 Rail Installation
  • High accuracy level
  • RS485 communication /ModBus RTU
  • Transformer input
  • Matching with inverter
  •  All or More Functions Customizable

 

Voltage

AC 57.7/100V、220/380V

 

Over load:1.2 times rated value(continuous):2 times rated value /1second:

 

Power consumption:<0.5VA(each channel)

 

Current

AC 1.5(6)A、100A/20mA、200A/100m etc

 

Over load:1.2 times rated Value(continuous):10 times rated Value/1second.

 

Power consumption: <0.5VA(each channel)

Accuracy

Voltage, Current, Power

Grade: 0.5

Active Power

Grade: 1 

Reactive Power

Grade: 2

Wiring Type

Three phase 3 line, Three phase 3 line

Frequency

45-65Hz

Power Supply

Working Range: AC/DC 85V~265V

Power Consumption: main body ≤5VA

Relay Output

Contact Mode: normally open(level output)

Contact Capacity: AC 250V/3A DC 30N/3A

Power Pulse Output

Output mode: optocoupler pulse with open collector

Switch Value Input

Support dry contact input, inner DC12V power supply

Communication

RS485 interface, support Modbus-RU protocol

Security

Power Frequency withstand Voltage

Among APS, voltage signal, current signal: AC 2kW/lmin:

Among switch value, pulse output, communication: AC 1KV/1min

Insulation

resistance

input, output to chassis>10MQ

Electromagnetic Compatibility Level

Comply with IEC 61000 standard(grade 3)

Protection Level

IP30

Working Environment

Temperature: -25℃~+70℃;

Display screen temperature: -20℃~+70℃;

Storage: -40℃~+85℃;

Relative Humidity: ≤95% no condensation;

Elevation: ≤2500.

INSTALL AND DIMENTION  

     Standard rail installation

TERMINAL DEFINING AND WIRING

 

 

DTSD9866-CD4-NL Three Phase Anti-backcurrent Smart Power Meter

Baidu
sogou